  • All in 1- Off Grid / On Grid & Hybrid Bi-Directional solution
  • Automatic Superfast switching time (Changeover Time) 4ms. It can be used as UPS
  • Battery Management System (BMS) to protect & enhance the battery life (Li-ion/Lead Acid/Li P04)
  • 100% unbalanced output, each phase; Max. output up to 50% rated power (Three Phase)
  • Colourful touch LCD display with ease of operation & maintenance.
  • Ideal solution for BLACK-OUT & BROWN-OUTS with GRID Exports with & without Battery.
  • Programmable supply priority for PV, Battery & Grid.
  • Inbuilt Zero Export / Reverse Power Limit to grid.
  • Grid Peak Compensation Mode – It can reduce / Limit Maximum Demand (save your penalties)
  • Intelligent SMART LOAD function for Air Conditioner, Geyser, Grid tie inverter & Home Appliances.
  • DC couple and AC couple to retrofit existing solar system
  • Max. 16pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
  • Max. charging/discharging current upto 240A
  • 48V low voltage battery, transformer isolation design
  • 6 times period for battery charging / discharging
  • Vector/frequency drop control.
  • Supports using diesel generator to charge the battery directly. ensuring system energy supply 24*7Hrs
  • Max. Conversion efficiency of 97.6%; Max. battery charge efficiency of 95.5%
  • Support storing energy from diesel generator.

Hybrid Inverter Three Phase (5/6/8/10/12/15/20/25/30/50 KW)

Technical Specification – Hybrid Inverter Three Phase

Three Phase
CAPACITY (KW) 5KW 48V 6KW 48V 8KW 48V 10KW 48V 12KW 48V 15KW 48V
MODEL NUMBER MLS-HY05T MLS-HY06T MLS-HY08T MLS-HY10T MLS-HY12T MLS-HY15T
BATTERY INPUT DATA
Battery Type Lead-acid or Li-lon
Battery Voltage Range (V) 40~60
Max. Charging Current (A) 120 150 190 210 240 270
Max. Discharging Current (A) 120 150 190 210 240 270
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-IonBattery Self-adaption to BMS
PV STRING INPUT DATA
Max. DC Input Power (W) 6500 7800 10400 13000 15600 18000
Rated PV Input Voltage (V) 550 (160~800)V
Start-up Voltage (V) 160
MPPT Voltage Range (V) 200-650
Full Load DC Voltage Range (V) 350-650
PV Input Current (A) 13+13 26+13
Max. PV Isc Current (A) 17+17 34+17
Number of MPPT/Strings per MPPT 2/1+1 2/2+1
AC OUTPUT DATA
Rated AC Output and UPS Power (W) 5000 6000 8000 10000 12000 15000
Max. AC Output Power (W) 5500 6600 8800 11000 13200 16500
AC Output Rated Current (A) 7.2 8.7 11.6 14.5 17.4 21.8
Max. AC Output Current (A) 8 9.6 12.8 15.9 19.1 24
Max. Continuous AC Passthrough Current (A) 45 8
Peak Power (off grid) 1.5 time of rated power, 10 S
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
DC injection current (mA) >0.5%IN
EFFICIENCY
Max Efficiency (%) 97.60%
Euro Efficiency (%) 97%
MPPT Efficiency (%) 99.90%
PROTECTION
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection .
Output Over Voltage Protection DC Type II/AC Type III
GENERAL DATA
Operating Temperature Range (°C) -45~60°C, >45°C derating
Cooling Smart Cooling
Noise (dB) ≤ 45db ≤ 55db
Communication with BMS RS485; CAN
Weight (kg) 33.6 30.5
Size (mm) 422W x 702H x 281D
Protection Degree IP65
Installation Style Wall-mounted
Standard Warranty 5 Years (Extendable upto 10 Years)