Hybrid Inverter Three Phase
MLS(HY15T-HY25T) 15-25.0KW
Hybrid Inverter Three Phase
MLS(HY15T-HY25T) 15-25.0KW
- All in 1- Off Grid / On Grid & Hybrid Bi-Directional solution
- Automatic Superfast switching time (Changeover Time) 4ms. It can be used as UPS
- Battery Management System (BMS) to protect & enhance the battery life (Li-ion/Lead Acid/Li P04)
- 100% unbalanced output, each phase; Max. output up to 50% rated power (Three Phase)
- Colourful touch LCD display with ease of operation & maintenance.
- Ideal solution for BLACK-OUT & BROWN-OUTS with GRID Exports with & without Battery.
- Programmable supply priority for PV, Battery & Grid.
- Inbuilt Zero Export / Reverse Power Limit to grid.
- Grid Peak Compensation Mode – It can reduce / Limit Maximum Demand (save your penalties)
- Intelligent SMART LOAD function for Air Conditioner, Geyser, Grid tie inverter & Home Appliances.
- DC couple and AC couple to retrofit existing solar system
- Max. 16pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
- Max. charging/discharging current upto 240A
- 48V low voltage battery, transformer isolation design
- 6 times period for battery charging / discharging
- Vector/frequency drop control.
- Supports using diesel generator to charge the battery directly. ensuring system energy supply 24*7Hrs
- Max. Conversion efficiency of 97.6%; Max. battery charge efficiency of 95.5%
- Support storing energy from diesel generator.
Hybrid Inverter Three Phase (5/6/8/10/12/15/20/25/30/50 KW)
Technical Specification – Hybrid Inverter Three Phase
Three Phase | ||||||
CAPACITY (KW) | 25KW HV | |||||
---|---|---|---|---|---|---|
MODEL NUMBER | MLS-HY25T | |||||
BATTERY INPUT DATA | ||||||
Battery Type | Li-Ion/Li-Po4 | |||||
Battery Voltage Range (V) | 160~700 | |||||
Max. Charging Current (A) | 50 | |||||
Max. Discharging Current (A) | 50 | |||||
Charging Curve | 3 Stages / Equalization | |||||
Charging Strategy for Li-IonBattery | Self-adaption to BMS | |||||
PV STRING INPUT DATA | ||||||
Max. DC Input Power (W) | 32500 | |||||
Rated PV Input Voltage (V) | 1000V | |||||
Start-up Voltage (V) | 180 | |||||
MPPT Voltage Range (V) | 150-850 | |||||
Full Load DC Voltage Range (V) | 625-850 | |||||
PV Input Current (A) | 26+26 | |||||
Max. PV Isc Current(A) | 39+39 | |||||
Number of MPPT/Strings per MPPT | 2/2+2 | |||||
AC OUTPUT DATA | ||||||
Rated AC Output and UPS Power (W) | 25000 | |||||
Max. AC Output Power (W) | 26000 | |||||
AC Output Rated Current (A) | 36.3 | |||||
Max. AC Output Current (A) | 39.9 | |||||
Max. Continuous AC Passthrough Current (A) | 80 | |||||
Peak Power (off grid) | 1.5 time of rated power, 10 S | |||||
Power Factor | 0.8 leading to 0.8 lagging | |||||
Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | |||||
Grid Type | Three Phase | |||||
DC injection current (mA) | <0.5% IN | |||||
EFFICIENCY | ||||||
Max. Efficiency | 97.60% | |||||
Euro Efficiency | 97% | |||||
MPPT Efficiency | 99.90% | |||||
PROTECTION | ||||||
Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection . | |||||
Output Over Voltage Protection | DC Type II/AC Type III | |||||
GENERAL DATA | ||||||
Operating Temperature Range (°C) | -45~60°C, >45°C derating | |||||
Cooling | Smart Cooling | |||||
Noise (dB) | ≤ 55db | |||||
Communication with BMS | RS485; CAN | |||||
Weight (kg) | 30.5 | |||||
Size (mm) | 408W x 638H x 237D | |||||
Protection Degree | IP65 | |||||
Installation Style | Wall-mounted | |||||
Standard Warranty | 5 Years (Extendable upto 10 Years) |